Белорусский национальный технический университет
Repository of the Belarusian National Technical University
ISSN: 2310-7405
Repository of the Belarusian National Technical University
View Item 
  •   Repository BNTU
  • Внеуниверситетские публикации ученых БНТУ
  • Публикации в изданиях Республики Беларусь
  • View Item
  •   Repository BNTU
  • Внеуниверситетские публикации ученых БНТУ
  • Публикации в изданиях Республики Беларусь
  • View Item
JavaScript is disabled for your browser. Some features of this site may not work without it.

Исследование влияния низкоинтенсивного импульсного ультразвука на смачиваемость поверхности титановых дентальных имплантатов в эксперименте

Thumbnail
Authors
Рубникович, С. П.
Хомич, И. С.
Минченя, В. Т.
Date
2016
Publisher
БГУИР
Another Title
The study of low-intensity pulsed ultrasound influence on wettability of titanium dental implants’ surface in experimental model
Bibliographic entry
Рубникович, С. П. Исследование влияния низкоинтенсивного импульсного ультразвука на смачиваемость поверхности титановых дентальных имплантатов в эксперименте = The study of low-intensity pulsed ultrasound influence on wettability of titanium dental implants’ surface in experimental model / С. П. Рубникович, И. С. Хомич, В. Т. Минченя // Доклады БГУИР. – 2016. – № 7. – С. 2013-2017.
Abstract
В статье представлены результаты экспериментальных исследований, при которых изучено влияние низкоинтенсивного импульсного ультразвука на смачиваемость поверхности титановых дентальных имплантатов. Исследовали 64 титановых однородных дентальных имплантата. Контрольную группу составили 32 дентальных имплантатa без ультразвукового воздействия. В опытную группу вошли 32 дентальных имплантата, на которые воздействовали низкоинтенсивным импульсным ультразвуком.
Abstract in another language
The results of experimental studies, the purpose of which was to study the effect of low-intensity pulsed ultrasound on the wettability of the surface of titanium dental implants are described. We studied 64 titanium dental implants. The control group consisted of 32 dental implants without ultra-sonication. The experimental group consisted of 32 dental implants, which were exposed to low-intensity pulsed ultrasound. Studies using low-intensity pulsed ultrasound showed that the wettability of the surface of all the experimental samples (32 dental implant) was 100 %, and the wettability of control samples (32 dental implant) was not observed. Thus the previously unknown property of low intensity pulsed ultrasound enabling the wetting of entire surface of the dental implant was discovered.
URI
https://rep.bntu.by/handle/data/80739
View/Open
Issledovanie_vliyaniya_nizkointensivnogo_impulsnogo.pdf (139.8Kb)
Collections
  • Публикации в изданиях Республики Беларусь[3461]
Show full item record
CORE Recommender

Belarusian National Technical University | Science Library | About Repository | Размещение в Репозитории | Contact Us
Яндекс.МетрикаIP Geolocation by DB-IP
Science Library | About Repository | Размещение в Репозитории | Contact Us
 

Browse

All of Repository BNTUCommunities & CollectionsAuthorsTitlesBy Issue DatePublisherBy Submit DateTypeThis CollectionAuthorsTitlesBy Issue DatePublisherBy Submit DateType

My Account

LoginRegister

Belarusian National Technical University | Science Library | About Repository | Размещение в Репозитории | Contact Us
Яндекс.МетрикаIP Geolocation by DB-IP
Science Library | About Repository | Размещение в Репозитории | Contact Us