Now showing items 13-32 of 490

    • Application of the Correlation Measurement Method for Reconstructing of the Velocity Profile with Spatial and Temporal Discretization in Studies of the Hydrodynamics of Turbulent Flows Based on the Matrix Conductometry Method 

      Dmitriev, S. M.; Khrobostov, A. E.; Solncev, D. N.; Barinov, A. A.; Chesnokov, A. A.; Konovalov, I. A.; Makarov, M. A.; Zyryanova, T. K. (БНТУ, 2021)
      The correlation method for measuring of the coolant flow rate is used in the operation of nuclear power plants and is widespread in research practice including study of turbulent flows hydrodynamics. However the question of its applicability and possibilities in studies using the matrix conductometry method remains open. Earlier the algorithm for determining of the correlation ...
      2021-12-22
    • Application of the Correlation Velocity Measurements for Hydrodynamic Investigations of Turbulent Coolant Flow in Nuclear Reactor Elements 

      Konovalov, I. A.; Khrobostov, A. E.; Legchanov, M. A.; Solncev, D. N.; Barinov, A. A.; Ryazanov, A. V.; Chesnokov, A. A.; Makarov, M. A. (БНТУ, 2020)
      The method of correlation measurement of the coolant flow rate, widely used for operational diagnostics of nuclear power plants, can be extensively used in research practice. The aim of this work was to apply a correlation method based on the conductometric measurement system with wire-mesh sensors for measuring a coolant flow rate. Insignificant concentration of a salt solution ...
      2020-09-18
    • Application of the Hough Transform to Dispersion Control of Overlapping Particles and Their Agglomerates 

      Гуляев, П. В. (БНТУ, 2023)
      The dispersion control of micro- and nanoparticles by their images is of great importance for ensuring the specified properties of the particles themselves and materials based on them. The aim of this article was to consider the possibilities of using the Hough transform for dispersion control of overlapping particles and their agglomerates. Analysis of the application of the ...
      2023-10-18
    • Application of the Thermal Diffusivity Standard for the Heat Transfer Parameter Control in Absorbing Materials 

      Ivakin, E. V. (БНТУ, 2023)
      Metrological support creation and use of heat transfer etalons are important stages in the development of modern materials science. This is especially concerned to the emergence of new materials in the world with previously unattainable thermophysical parameters. The purpose of this work was to develop and experimentally verify the idea of joint application of the transient ...
      2023-10-17
    • Application of Two-Channel Principle in Measuring Devices to Compensate for Disturbing Influences of Unknown Physical Nature 

      Nesterov, V. N.; Li, A. R. (БНТУ, 2020)
      The article notes the advantages of the method of constructing absolutely invariant measuring transducers for working in conditions with disturbing influences. However, this method is not universal. Its limitations are due to the impossibility of "symmetric" transmission of all disturbing influences into parallel measuring channels. A broader interpretation of the two-channel ...
      2020-09-18
    • Assessing of a Radiation Therapy Sessionʼs Duration at the Stage of Pre-Radiation Preparation 

      Piatkevich, M. N.; Titovich, E. V. (БНТУ, 2022)
      The treatment planning process includes a review of the radiation treatment plan which leads to a decision on the patientʼs treatment technique. The scope of this study was to create a mathematical model for calculating of a radiation therapy session duration during the pre-radiation planning stage. For dosimetric planning of radiation treatment the authors provided a formula and ...
      2022-04-06
    • Assessment of Temperature Effects in Interior Orientation Parameters Calibration of Optoelectronic Devices 

      Starasotnikau, M. A. (БНТУ, 2020)
      A digital micromirror device (DMD) micromirrors periodic spatial structure is a measuring scale in interior orientation parameters calibration of optoelectronic devices problems, when using a DMD as a testobject. It is important that DMD micromirrors periodic spatial structure remains constant. Change in a DMD micromirrors spatial structure may occur due to heating. In addition ...
      2020-06-30
    • Automatic Measurement in Metallography 

      Anisovich, A.; Markevich, M.; Vanchinkhuu, Jigmeddorj (БНТУ, 2023)
      Quantitative analysis of the structure of metals and alloys is an important part of modern metal science. To obtain quantitative data and build dependencies, metallographic image processing programs are used, oriented both for scientific research and for use in industry. Programs capable of automatically performing metallographic analysis are of great interest to consumers. When ...
      2023-10-18
    • Autonomous Streaming Space Objects Detection Based on a Remote Optical System 

      Baranova, V. S.; Saetchnikov, V. A.; Spiridonov, A. A. (БНТУ, 2021)
      Traditional image processing techniques provide sustainable efficiency in the astrometry of deep space objects and in applied problems of determining the parameters of artificial satellite orbits. But the speed of the computing architecture and the functions of small optical systems are rapidly developing thus contribute to the use of a dynamic video stream for detecting and ...
      2021-12-22
    • Backscattering of Ultrasonic Waves as the Basis of the Method of Control of Structure and Physicо-Mechanical Properties of Cast Irons 

      Baev, A. R.; Levkovich, N. V.; Babuk, E. P.; Asadchaya, M. V. (БНТУ, 2023)
      Increasing the reliability of control of cast iron structure and its physical and mechanical characteristics is an important scientific and technical task of the machine-building industry. The paper studies the possibilities of controlling the structure of cast irons using structural noise created by ultrasonic scattering on graphite inclusions of different shapes. The subject ...
      2023-10-17
    • Broadband method for group velocity dispersion measurements in the mid-infrared 

      Klimentov, D. S.; Tolstik, N. A.; Dvoyrin, V. V.; Sorokina, I. T. (БНТУ, 2011)
      A setup for broadband measurements of dispersion parameter in optical fibers based on the Mach–Zehnder interferometer is developed. Tm-doped fiber pumped at 1.61 μm was used as a source of broadband emission, that allowed to achieve the measurement spectral range of 1700 to 2000 nm. The method is applicable for comparatively short pieces of optical fiber with lengths of less than ...
      2012-03-28
    • Calculation of Correction Factors for Vickers Hardness Measurements on a Non-Planar Surface 

      Sandomirski, S. G.; Val’ko, A. L.; Rudenko, S. P. (БНТУ, 2022)
      The exact determination of Vickers HV hardness is important for determining of the product material mechanical properties. An important aspect of measuring HV is to obtain its values on a non-planar surface. Regulatory documents contain table values of correction factors K which depend on the surface shape (convex or concave, spherical or cylindrical), its curvature (diameter D) ...
      2022-11-11
    • Calculation of the Effective Energy Release Centerʼs Position of Inorganic Scintillation Detectors for Calibration at Small “Source–Detector” Distances 

      Lukashevich, R.; Fokov, G. (БНТУ, 2021)
      Inorganic scintillation detectors are widely used to measure of dose rate in the environment due to their high sensitivity to photon radiation. A distinctive feature when using such detectors is the need to take into account of the position of the effective energy release center. This peculiarity is actual when using measuring instruments with inorganic scintillation detectors ...
      2021-10-15
    • Calculation of the Effective Energy Release Centerʼs Position of Inorganic Scintillation Detectors for Calibration at Small “Source–Detector” Distances 

      Lukashevich, R.; Fokov, G. (БНТУ, 2021)
      Inorganic scintillation detectors are widely used to measure of dose rate in the environment due to their high sensitivity to photon radiation. A distinctive feature when using such detectors is the need to take into account of the position of the effective energy release center. This peculiarity is actual when using measuring instruments with inorganic scintillation detectors ...
      2021-10-18
    • Compact 999.6 nm Actively Q-Switched Yb3+:LuAlO3 Laser for Laser-Induced Breakdown Spectroscopy 

      Rudenkov, Alexander; Kisel, Viktor; Yasukevich, Anatol; Hovhannesyan, Karine; Petrosyan, Ashot; Kuleshov, Nikolai (БНТУ, 2019)
      Compact actively Q-switched diode-pumped lasers based on Yb3+-materials are of practical importance for wide range of scientific, industrial and biomedical applications. The aim of this work was to study the Yb3+:LuAlO3 actively Q-switched laser. One of the most promising crystalline hosts for rare-earth ions are Perovskite-like aluminate crystals. Yttrium aluminate crystal YAlO3 ...
      2019-06-27
    • Compact Passively Q-Switched Tm:KY(WO4)2 Laser 

      Kisel, V. E. (БНТУ, 2022)
      Diode-pumped thulium lasers emitting in the spectral range near 2 μm are attractive for applications in different areas: surgery, rangefinding, and environmental atmosphere monitoring. In this article the latest results of Tm:KYW laser performance with a polycrystalline Cr:ZnSe as the most available saturable absorber for 2 μm spectral region are presented. A maximum continuous-wave ...
      2022-04-05
    • Compositionally Disordered Doped with Cerium Crystalline Garnet Type Materials for Brighter and Faster Scintillations 

      Korzhik, M. V. (БНТУ, 2021)
      Ce-doped tetracationic garnets (Gd, M)3Al2Ga3O12(M = Y, Lu) form a family of new multipurpose promising scintillation materials. The aim of this work was to evaluate the scintillation yield in the materials of quaternary garnets activated by cerium ions with partial isovalent substitution of the matrix-forming gadolinium ions by yttrium or lutetium ions. Materials were obtained ...
      2021-12-22
    • Concept of Vector Multicomponent Physical Quantities, Models and Measurement Method 

      Nesterov, V. N. (БНТУ, 2022)
      The paper presents a new view of vector physical quantities as multicomponent quantities. Each of the components of the mentioned multicomponent quantities can carry important and even unique information about the sources and causes of their occurrence. Looking at the vector quantity as the multicomponent quantity led to the need to form the corresponding conception. There are ...
      2022-12-29
    • Continuous-wave Laser on Er,Yb-Codoped Pentaborate Crystal 

      Gorbachenya, K. N.; Kisel, V. E.; Deineka, R. V.; Yasukevich, A. S.; Kuleshov, N. V.; Maltsev, V. V.; Mitina, D. D.; Volkova, E. A.; Leonyuk, N. I. (БНТУ, 2019)
      We report, for the first time to our knowledge, a diode-pumped continuous-wave microchip Er,Yb:YMgB5O10 laser. The purpose of this work was to study the growth technique, spectroscopic properties and continuous-wave laser performance of Er3+,Yb3+:YMgB5O10 novel crystal. Absorption and luminescence spectra as well as kinetics of luminescence decay were studied. Ytterbiumerbium ...
      2020-01-08
    • Correction of the Contribution of Scattered Photon Radiation to the Ionization Chamber Readings During X-Ray Radiation Quality Assessment 

      Zaharadniuk, A. A.; Senkovsky, K. G.; Lukashevich, R. V. (БНТУ, 2022)
      Reduction of the systematic error when determining the characteristics of the reference X-ray radiation fields is an essential task according to the ISO 4037-1:2019 standard. This task is especially important in dosimetry laboratories when establishing the qualities of reference photon fields. The aim of the study was to develop a method that allows taking into account the ...
      2022-11-11