Now showing items 1-1 of 1

    • Расчет параметров воздухонагревателей для контейнерных сушилок 

      Чеботарев, В. П.; Барановский, И. В.; Иванов, А. И. (БНТУ, 2009)
      The method of heat calculation and design data projected the furnace unit is developed. It is certain, that theoretically the furnace unit should have diameter furnace chambers of 0,71 m, diameter heat-exchanger 1,38 m, length of 2,22 m and to provide thermal productivity up to 500…600 thousand in ксаіф at combustion of diesel fuel of 60...80 kg/b.
      2021-09-22